Quantcast
Channel: Andrew Bell's Activities
Browsing all 4948 articles
Browse latest View live

Image may be NSFW.
Clik here to view.

CEU3 and CEU4 display problem.

There is an issue with the display of referenced dwgs in CEU3 using bylevel symbology. See below. The top one is from SS4, with the second one being the same sheet model in CEU3.

View Article


Image may be NSFW.
Clik here to view.

CONNECT Advisor message: Unable to get Bentley CONNECT Advisor subscription,...

Product(s):MicroStationVersion(s):10.04.00.46Environment:N\AArea:CONNECT IntegrationSubarea:CONNECT AdvisorNote: This article was created thanks to Jan SlegrProblem Description CONNECT Advisor displays...

View Article


compresses file on exit Config Variable

I cannot find a configuration variable to turn compress file one exit "on" by default for new and existing users.  Does one exist or doe sit have to be manually activated?

View Article

Image may be NSFW.
Clik here to view.

CE4 - Display Rules activation switch

Can we have the Display Rules selection list, On/Off options and the Display Rule setup icons moved to the main View Attributes dialog, rather than in the Display Styles dialog.I agree, the setup of...

View Article

Select By Attributes tool in Connect U3 has problems

The "Select By Attributes" tool in Connect Edition U3 on Windows 10 has problems: When I did a search (Upper Rt. of Ribbon) for the tool, where it told me I could find it does not exist in default...

View Article


Breaks are not recognized when extracting graphics and building triangles

I am trying to append a .dat file to include breaks.  I start in DTM>Extract>Graphics, and in the "Extract Graphics" window I use the following settings:  File Type:  Ascii, File Open:  Append,...

View Article

Microstation SS4 refuses to Install

I'm trying to install Microstation SS4, but it refuses to work.When I run the setup.exe, a dialog window pops up for a fraction of a second, and thats it.nothing else happens. I tried running as...

View Article

Image may be NSFW.
Clik here to view.

How to Link a level to a Reference attachment

   Applies To    Product(s):MICROSTATION Version(s):08.01.01.09 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group  ProblemHow to Link a level to a Reference...

View Article


Image may be NSFW.
Clik here to view.

How to turn ON / OFF reference display

   Applies To    Product(s):MicroStation Version(s):08.05.02.35 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group  ProblemHow to turn off, turn on or toggle...

View Article


Image may be NSFW.
Clik here to view.

If same dwg file is referenced twice turning off display of one turns off...

   Applies To    Product(s):MICROSTATION Version(s):V8, V8i Environment: N\A Area: References Subarea: N\A Original Author:Bentley Technical Support Group  ProblemIf the same dwg file is referenced...

View Article

Image may be NSFW.
Clik here to view.

How to use reference file level symbology overrides without affecting the...

   Applies To    Product(s):MICROSTATION Version(s):All Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group  ProblemHow to use reference file level symbology...

View Article

Image may be NSFW.
Clik here to view.

MicroStation Reference File [FAQ]

 Product:MicroStation Version:All Environment:N\A Area:Reference Subarea:GeneralHow can I use Saved Views to save the display on/off state of Reference attachments?See Using Saved Views To Control...

View Article

Image may be NSFW.
Clik here to view.

Nested references are being loaded although nest depth is set to 0

   Applies To    Product(s):MicroStation Version(s):08.00.00.00 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group  ProblemNested references are being loaded...

View Article


Image may be NSFW.
Clik here to view.

How is this file path of the mapping Image File stored in an i-model?

   Applies To    Product(s):MicroStation Version(s):08.11.07.443 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group  ProblemHow is this file path of the...

View Article

Image may be NSFW.
Clik here to view.

Reference Activate

 Product:MicroStation Version:V8i Environment:N\A Area:Reference Subarea:N\A[Please note this tip is largely superseded by the Reference Activation options in the right-press context menu] Here is...

View Article


Image may be NSFW.
Clik here to view.

Referenced DWG to DGN Coordinates Do Not Match

   Applies To    Product(s):MicroStation Version(s):08.11.07.446 Environment: N\A Area: Reference Subarea: N\A Original Author:EC, Bentley Technical Support Group   BackgroundEven when the coordinates...

View Article

Image may be NSFW.
Clik here to view.

Referencing 3D DWG files to 2D design files, elements are not correctly display

 Product:MicroStation Version:V8i Environment:N\A Area:Reference Subarea:N\AProblemI am trying to reference AutoCAD DWG files into MicroStation. Unfortunately, elements are not  being properly...

View Article


Image may be NSFW.
Clik here to view.

Save as V8 or DWG merging reference levels that are off are being copied into...

   Applies To    Product(s):MICROSTATION Version(s):08.05.01.25 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group  ProblemOn selecting Save as (V8 or DWG),...

View Article

Image may be NSFW.
Clik here to view.

Set reference start in folder when attaching references

   Applies To    Product(s):MicroStation Version(s):08.08.04.44 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group  ProblemHow to set reference start in...

View Article

Image may be NSFW.
Clik here to view.

Using Saved Views To Control Reference Display

 Product:MicroStation Version:10.00.00.25 Environment:N\A Area:Installation Subarea:GeneralProblemMany users have asked to save the display on/off state of Reference attachments in Saved Views....

View Article
Browsing all 4948 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>