CEU3 and CEU4 display problem.
There is an issue with the display of referenced dwgs in CEU3 using bylevel symbology. See below. The top one is from SS4, with the second one being the same sheet model in CEU3.
View ArticleCONNECT Advisor message: Unable to get Bentley CONNECT Advisor subscription,...
Product(s):MicroStationVersion(s):10.04.00.46Environment:N\AArea:CONNECT IntegrationSubarea:CONNECT AdvisorNote: This article was created thanks to Jan SlegrProblem Description CONNECT Advisor displays...
View Articlecompresses file on exit Config Variable
I cannot find a configuration variable to turn compress file one exit "on" by default for new and existing users. Does one exist or doe sit have to be manually activated?
View ArticleCE4 - Display Rules activation switch
Can we have the Display Rules selection list, On/Off options and the Display Rule setup icons moved to the main View Attributes dialog, rather than in the Display Styles dialog.I agree, the setup of...
View ArticleSelect By Attributes tool in Connect U3 has problems
The "Select By Attributes" tool in Connect Edition U3 on Windows 10 has problems: When I did a search (Upper Rt. of Ribbon) for the tool, where it told me I could find it does not exist in default...
View ArticleBreaks are not recognized when extracting graphics and building triangles
I am trying to append a .dat file to include breaks. I start in DTM>Extract>Graphics, and in the "Extract Graphics" window I use the following settings: File Type: Ascii, File Open: Append,...
View ArticleMicrostation SS4 refuses to Install
I'm trying to install Microstation SS4, but it refuses to work.When I run the setup.exe, a dialog window pops up for a fraction of a second, and thats it.nothing else happens. I tried running as...
View ArticleHow to Link a level to a Reference attachment
Applies To Product(s):MICROSTATION Version(s):08.01.01.09 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group ProblemHow to Link a level to a Reference...
View ArticleHow to turn ON / OFF reference display
Applies To Product(s):MicroStation Version(s):08.05.02.35 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group ProblemHow to turn off, turn on or toggle...
View ArticleIf same dwg file is referenced twice turning off display of one turns off...
Applies To Product(s):MICROSTATION Version(s):V8, V8i Environment: N\A Area: References Subarea: N\A Original Author:Bentley Technical Support Group ProblemIf the same dwg file is referenced...
View ArticleHow to use reference file level symbology overrides without affecting the...
Applies To Product(s):MICROSTATION Version(s):All Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group ProblemHow to use reference file level symbology...
View ArticleMicroStation Reference File [FAQ]
Product:MicroStation Version:All Environment:N\A Area:Reference Subarea:GeneralHow can I use Saved Views to save the display on/off state of Reference attachments?See Using Saved Views To Control...
View ArticleNested references are being loaded although nest depth is set to 0
Applies To Product(s):MicroStation Version(s):08.00.00.00 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group ProblemNested references are being loaded...
View ArticleHow is this file path of the mapping Image File stored in an i-model?
Applies To Product(s):MicroStation Version(s):08.11.07.443 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group ProblemHow is this file path of the...
View ArticleReference Activate
Product:MicroStation Version:V8i Environment:N\A Area:Reference Subarea:N\A[Please note this tip is largely superseded by the Reference Activation options in the right-press context menu] Here is...
View ArticleReferenced DWG to DGN Coordinates Do Not Match
Applies To Product(s):MicroStation Version(s):08.11.07.446 Environment: N\A Area: Reference Subarea: N\A Original Author:EC, Bentley Technical Support Group BackgroundEven when the coordinates...
View ArticleReferencing 3D DWG files to 2D design files, elements are not correctly display
Product:MicroStation Version:V8i Environment:N\A Area:Reference Subarea:N\AProblemI am trying to reference AutoCAD DWG files into MicroStation. Unfortunately, elements are not being properly...
View ArticleSave as V8 or DWG merging reference levels that are off are being copied into...
Applies To Product(s):MICROSTATION Version(s):08.05.01.25 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group ProblemOn selecting Save as (V8 or DWG),...
View ArticleSet reference start in folder when attaching references
Applies To Product(s):MicroStation Version(s):08.08.04.44 Environment: N\A Area: Reference Subarea: N\A Original Author:Bentley Technical Support Group ProblemHow to set reference start in...
View ArticleUsing Saved Views To Control Reference Display
Product:MicroStation Version:10.00.00.25 Environment:N\A Area:Installation Subarea:GeneralProblemMany users have asked to save the display on/off state of Reference attachments in Saved Views....
View Article