Applies To | |||
Product(s): | MicroStation | ||
Version(s): | 08.05.01.25 | ||
Environment: | N\A | ||
Area: | Configuration | ||
Subarea: | General | ||
Original Author: | Bentley Technical Support Group | ||
Problem
Error message "Expanded line too long" when opening file OR
what is the maximum expanded path?
Product: MicroStation V8 2004 Edition
Version: 08.05.01.25
Area: Other
Solution
This error message is caused by configuration variables length
that exceeds the limit defined in MicroStation source code.
Limits:
Maximum line length (this is the longest that a line can be in a
MicroStation configuration file) = 2048
Maximum macro length (this is the longest expanded value that
MicroStation can handle) = 31744
Available memory can also play a role in this, because the
memory in which MicroStation stores the cfg vars and their
values is allocated at runtime.