Applies To | |||
Product(s): | MicroStation | ||
Version(s): | 08.00.00.21 | ||
Environment: | N\A | ||
Area: | Drawing Aids | ||
Subarea: | N\A | ||
Original Author: | Bentley Technical Support Group | ||
Problem
AccuDraw Indexing is not working.
AccuDraw Axis and/or Distance Indexing is not working.
Solution
Increase the tolerance setting.
Possible solutions
-Enable Indexing
1. Go to Settings > AccuDraw > Coordinates
2. Toggle on Axis and/or Distance in the Indexing section.
-Make sure the Indexing tolerance is greater then 1.
1. Go to Settings > AccuDraw > Coordinates
2. Change tolerance setting to be larger then 1
Notes:
-AccuDraw indexing still works when the tolerance is set to ~1 but the low setting does not have enough tactile "locking" to know that it is actually locking the axis.