Product: | MicroStation | ||
Version: | 08.11.07.443 | ||
Environment: | N\A | ||
Area: | Configuration | ||
Subarea: | Workspaces |
Problem
Project template not found.
This error occurs when attempting to create a new project from MicroStation Manager.
Solution
Move Project.template into project folder.
Error is caused by:
Location of _USTN_PROJECTROOT does not contain "project.template" file.
1. Locate the delivered "project.template" file.
The typical location is here:
C:\programdata\Bentley\MicroStation V8i (SELECTseries)\Workspace\projects\
2. Browse to location of project folders.
The location of the project folders is defined by the following configuration variable: _USTN_PROJECTROOT.
3. Copy the "project.template" file from delivered location (step #1) to the project folders location (step #2).
Note:
When a project is created, the associated project configuration file (.PCF) is populated by the project template file. It is required in order to create a new project.
See also
Other language sources
Original Author: | Bentley Technical Support Group |