Problem Description:
I would like to know the commands to turn off (and on) a particular level in a particular reference file on a sheet model; eg. Reference file name "TestV08.dgn". I want to turn off the "Preliminary" level in that reference file on all sheets.
Solution:
Logical name of reference at Sheet model as REF and the logical names of the sheet attachments as ISO and TOP
Command line for Batch Process:
LEVEL SET DISPLAY OFF file:"testV08.dgn" Preliminary;SELVIEW ALL;FILEDESIGN
REFERENCE LEVELS OFF PRELIMINARY REF->ISO;SELVIEW ALL;FILEDESIGN
REFERENCE LEVELS OFF PRELIMINARY REF->TOP;SELVIEW ALL;FILEDESIGN