Batch Process: command to turn off a particular level in a sheet model

$
0
0
 Product:MicroStation
 Version:V8, 2004, XM, V8i, CONNECT
 Environment:N\A
 Area:Batch Processing
 Subarea:N\A

Problem Description:

I would like to know the commands to turn off (and on) a particular level in a particular reference file on a sheet model; eg. Reference file name "TestV08.dgn". I want to turn off the "Preliminary" level in that reference file on all sheets.

 

Solution:

Logical name of reference at Sheet model as REF  and the logical names of the sheet attachments as ISO and TOP



Command line for Batch Process:

LEVEL SET DISPLAY OFF file:"testV08.dgn" Preliminary;SELVIEW ALL;FILEDESIGN

REFERENCE LEVELS OFF PRELIMINARY REF->ISO;SELVIEW ALL;FILEDESIGN

REFERENCE LEVELS OFF PRELIMINARY REF->TOP;SELVIEW ALL;FILEDESIGN