Product(s): | MicroStation | ||
Version(s): | 10.14.00.86 | ||
Environment: | N\A | ||
Area: | CONNECT Advisor | ||
Subarea: | N\A |
Problem Description
CONNECT Advisor window pops up each time MicroStation is started, even though the automatic start is turned off in CONNECT Advisor settings.
Steps to Resolve
Perform the following steps:
1. Open Notepad as an Administrator.
2. Right click Notepad and “Run as Administrator”
3. Open file “C:\Program Files\Bentley\MicroStation CONNECT Edition\MicroStation\config\system\applicationload.cfg”
4. Search for “ConnectAdvisor”You will find this line “_USTN_FIRSTDGNFILE > ConnectAdvisor”
5. Add a Hash symbol “#_USTN_FIRSTDGNFILE > ConnectAdvisor” to the start of the line
6. File > Save
See Also
Other language sources
Original Author: | Grzegorz Cwiek |