Unable to create a CSV collection from the design file

$
0
0
 Product:MicroStation
 Version:08.11.09.459
 Environment:N\A
 Area:Levels
 Subarea:General

Problem Description

When I create or edit a CSV file and try to import levels from Design File via Macro button of "Level" column I receive following error messages:

1) Unable to create a collection from the design file for column: Level
2) This column already contains all the values from the design file.

I already marked Macros from "Bentley Systems" as Trusted ones

Steps to Resolve

The reason for the Problem is that user started MicroStation with "High Security" shortcut.
For this shortcut Variable MS_SECURITY_LEVELis set to "HIGH".
Please use blank MicroStation shortcut to start MicroStation without any Security Level.

The same problem also occurs when this variable MS_SECURITY_LEVEL is set to "HIGH" in any MicroStation configuration file.